Home

New Products

Contact Us

Power Analysis

Cable Faults

High Voltage

Redskye Products

Service List

Supported Products

Spares

Downloads

Related Links

VLF cable test set HVA30

Product Summary

 

High voltage cable test set VLF and DC

 

product code : RSKHVA30

Price: TBA

Features

 

HVA30

 

VLF and DC Hipot Instrument

 

THE vlf set for 11kV networks.

 

Find Weak Cables Without Making Cables Weak!

The single piece HVA30 is not only the most advanced high voltage VLF (Very Low Frequency) test system available; it is also the lightest, most compact instrument of its type on the market.

Although primarily designed for the AC Hipot testing of extruded Medium Voltage cable systems - according to the new IEEE400 and international testing standards where the application of high voltage DC is no longer recommended - the multi-output HVA30 is also suitable for testing transformers, switchgear, rotating machines and other electrical apparatus.

The instrument offers fully automatic Testing Sequences which allow the operator to effortlessly apply the correct testing standards without having to remember what those testing parameters are, thus avoiding possible over stressing of the cable system.

 

Standard features like built in storage of test results, smooth load independent and symmetrical Sinewave HV outputs, DC and AC VLF outputs, capacitance and insulation resistance (mega-ohmmeter) measurements, accurate RMS metering, integrated discharge and transient protection, all make this instrument the most sophisticated and easiest to use VLF instrument available.

 

Optional items include a small portable power pack to supply the HVA30 when a standard 110V AC mains supply is not available. No other VLF unit on the market offers this option!

In addition a portable Tan Delta system can be used with the HVA30 for additional cable testing and cable diagnostic capabilities.

 

FEATURES:

 

Smallest, lightest, most advanced universal high voltage test instrument available.

 

VLF (0.1Hz), DC (+/-), Cable Fault Conditioning (Burning), and Sheath/Jacket Testing modes all included.

Fully Automatic or manual cable test sequences

True Symmetrical Sinusoidal, load independent, output waveform across the full load range.

Real-time oscilloscope display of actual output waveform

Easy to use, ergonomic, menu guided, large backlit user interface

Rugged, one-piece design for easy portability

Large output load capability (up to 5uF)

Automatic and integrated load capacitance measurement with optimum frequency selection.

Integrated memory for storage of test results that can be downloaded to a PC/laptop at a later time.

No oil filled components or arcing contacts that require routine maintenance

Short circuited protected with active arc management regulation that avoids the usual nuisance tripping of conventional HV test equipment when a dielectric failure occurs.

 

Applications:

 

Ideal entry level very portable VLF set.

Perfect for systems such as 11kV

1.7U0 capable for up to 22kV networks

3.5U0 capable for up to 11kV networks

Expansion with partial discharge and tan delta accessories

HVA HVA30 vlf 0.1Hz high voltage cable test set

HVA30

View/Print  Datasheet

Here

HV discharge rod for the HVA30

Recommended accessory for

ensuring cables are fully discharged.

Flight case and Accessory case for the HVA30

Optional case, protects the instrument and accessories.

HVA series front panel